Abstract

BACKGROUND Wound closure after excision is commonly done with sutures or staples. A new sutureless innovative wound closure system is available for sutureless skin closure. OBJECTIVE To evaluate wound healing, patient comfort, and cosmetic results of a foil flip-over system for excision of small skin lesion. MATERIALS AND METHODS Patients presenting to the department of Dermatology of Erasmus University Medical Center, Rotterdam, The Netherlands for skin surgery during a 1.5-year period were prospectively studied. Key outcome measures were wound healing, patient comfort, and cosmetic results. Three independent physicians scored photographs of the scars. Evaluation tools used were comfort and body image questionnaires and visual analogue scales. RESULTS Ninety-six patients with 103 lesions were included in our study. The surgeon scored wound healing as excellent or good in 96%. No wound infections occurred. Ninety-two percent of patients scored removal of the system as comfortable. Median patient grade of scar after 1 month was 8 out of 10 points (interquartile range [IQR] 79). Median independent physician grade of photographs of the scars was 7.7 (IQR 7.18.0). CONCLUSION Sutureless foil flip-over is promising, with excellent patient comfort characteristics and good to excellent cosmetic results.
Original languageUndefined/Unknown
Pages (from-to)1829-1834
Number of pages6
JournalDermatologic Surgery
Volume38
Issue number11
DOIs
Publication statusPublished - 2012

Cite this