Acute procedural efficacy and safety of a novel cryoballoon for the treatment of paroxysmal atrial fibrillation: Results from the POLAR ICE study

  • Claire A. Martin*
  • , Roland R.R. Tilz
  • , the POLAR ICE Investigators
  • , Ante Anic
  • , Pascal Defaye
  • , Armin Luik
  • , Carlo de Asmundis
  • , Laure Champ-Rigot
  • , Saverio Iacopino
  • , Philipp Sommer
  • , Elizabeth M. Albrecht
  • , Jonathan D. Raybuck
  • , Elizabeth Richards
  • , Nele Cielen
  • , Sing Chien Yap
  • *Corresponding author for this work
  • Royal Papworth Hospital NHS Foundation Trust
  • University Heart Center Lübeck
  • Munich Heart Alliance; partner site Munich
  • Split University Hospital
  • Université Grenoble Alpes
  • Städtischen Klinikum Karlsruhe
  • Universitair Ziekenhuis Brussel (Campus Jette)
  • Normandie Université
  • Maria Cecilia Hospital
  • Ruhr University Bochum
  • Boston Scientific (Minnesota)

Research output: Contribution to journal › Article › Academic › peer-review

21 Citations (Scopus)
130 Downloads (Pure)

Abstract

Introduction: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. Methods: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. Results: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged −56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. Conclusion: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.

Original languageEnglish
Pages (from-to)833-840
Number of pages8
JournalJournal of Cardiovascular Electrophysiology
Volume34
Issue number4
Early online date14 Feb 2023
DOIs
Publication statusPublished - Apr 2023

Bibliographical note

Funding Information:
The authors would like to thank the entirety of the POLAR ICE study team, Boston Scientific field clinical specialists, local investigators, and local centers' personnel for their effort on this project. This study (ClinicalTrials.gov Identifier: NCT04250714) was initiated and sponsored by Boston Scientific.

Publisher Copyright:
© 2023 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC.

Fingerprint

Dive into the research topics of 'Acute procedural efficacy and safety of a novel cryoballoon for the treatment of paroxysmal atrial fibrillation: Results from the POLAR ICE study'. Together they form a unique fingerprint.

Cite this