TY - JOUR
T1 - Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System
AU - Piazza, Nick
AU - Otten, A
AU - Schultz, Carl
AU - Onuma, Yoshinobu
AU - Garcia Garcia, Hector
AU - Boersma, Eric
AU - de Jaegere, Peter
AU - Serruys, PWJC (Patrick)
PY - 2010
Y1 - 2010
N2 - Background: Anecdotal evidence suggests that transcatheter aortic valve implantation (TAVI) is being used beyond pre-market label indications. Methods: To assess the frequency and outcomes associated with "off-label" use of TAVI, we conducted a retrospective study, examining adherence to patient selection criteria in 63 patients undergoing implantation with the 18F CoreValve ReValving System (CRS). Label status (on-label vs off-label) was determined by following (1) inclusion/exclusion criteria indicated in the 18F CRS safety and efficacy trial and (2) a patient selection matrix indicating anatomical boundaries to guide patient selection. Off-label use was defined as the presence of at least one exclusion criterion or "non-acceptable" criteria based on the patient selection matrix. Results: Off-label implantation was identified in 42 patients (67%)-40% had one, 19% had two and 8% had three or more off-label criteria. Baseline demographics were similar between the groups except for a higher logistic EuroSCORE in the on-label group (19.8 (11.2) vs 14.5 (7.3), p = 0.029). There was no significant difference in the procedural success rates between the on-label and off-label groups (91% vs 95%, respectively, p = 0.47). The frequency of angiographic moderate-severe aortic regurgitation, post-implant dilatation or implantation of a second valve was also similar between the groups. At 30 days, the cumulative death rate was 10%; there were four deaths in the "on-label" and three deaths in the "off-label" group. Conclusion: In this study we found that "off-label" implantation of the CRS was common. Further studies are needed to evaluate the consequences of "label status" for patients undergoing TAVI.
AB - Background: Anecdotal evidence suggests that transcatheter aortic valve implantation (TAVI) is being used beyond pre-market label indications. Methods: To assess the frequency and outcomes associated with "off-label" use of TAVI, we conducted a retrospective study, examining adherence to patient selection criteria in 63 patients undergoing implantation with the 18F CoreValve ReValving System (CRS). Label status (on-label vs off-label) was determined by following (1) inclusion/exclusion criteria indicated in the 18F CRS safety and efficacy trial and (2) a patient selection matrix indicating anatomical boundaries to guide patient selection. Off-label use was defined as the presence of at least one exclusion criterion or "non-acceptable" criteria based on the patient selection matrix. Results: Off-label implantation was identified in 42 patients (67%)-40% had one, 19% had two and 8% had three or more off-label criteria. Baseline demographics were similar between the groups except for a higher logistic EuroSCORE in the on-label group (19.8 (11.2) vs 14.5 (7.3), p = 0.029). There was no significant difference in the procedural success rates between the on-label and off-label groups (91% vs 95%, respectively, p = 0.47). The frequency of angiographic moderate-severe aortic regurgitation, post-implant dilatation or implantation of a second valve was also similar between the groups. At 30 days, the cumulative death rate was 10%; there were four deaths in the "on-label" and three deaths in the "off-label" group. Conclusion: In this study we found that "off-label" implantation of the CRS was common. Further studies are needed to evaluate the consequences of "label status" for patients undergoing TAVI.
U2 - 10.1136/hrt.2009.172809
DO - 10.1136/hrt.2009.172809
M3 - Article
C2 - 19744965
SN - 1355-6037
VL - 96
SP - 19
EP - 26
JO - Heart
JF - Heart
IS - 1