"Compression-only" behavior: A second-order nonlinear response of ultrasound contrast agent microbubbles

J Sijl, M Overvelde, B Dollet, V Garbin, Nico Jong, D Lohse, M Versluis

Research output: Contribution to journalArticleAcademicpeer-review

67 Citations (Scopus)

Abstract

Oscillating phospholipid-coated ultrasound contrast agent microbubbles display a so-called " compression-only" behavior, where it is observed that the bubbles compress efficiently while their expansion is suppressed. Here, a theoretical understanding of the source of this nonlinear behavior is provided through a weakly nonlinear analysis of the shell buckling model proposed by Marmottant et al. [J. Acoust. Soc. Am. 118, 3499-3505 (2005)]. It is shown that the radial dynamics of the bubble can be considered as a superposition of a linear response at the fundamental driving frequency and a second-order nonlinear low-frequency response that describes the negative offset of the mean bubble radius. The analytical solution deduced from the weakly nonlinear analysis shows that the compression-only behavior results from a rapid change of the shell elasticity with bubble radius. In addition, the radial dynamics of single phospholipid-coated microbubbles was recorded as a function of both the amplitude and the frequency of the driving pressure pulse. The comparison between the experimental data and the theory shows that the magnitude of compression-only behavior is mainly determined by the initial phospholipids concentration on the bubble surface, which slightly varies from bubble to bubble. (C) 2011 Acoustical Society of America. [DOI:10.1121/ 1.3505116]
Original languageUndefined/Unknown
Pages (from-to)1729-1739
Number of pages11
JournalJournal of the Acoustical Society of America
Volume129
Issue number4
DOIs
Publication statusPublished - 2011

Cite this