Consecutive CT in vivo lung imaging as quantitative parameter of influenza vaccine efficacy in the ferret model

Edwin Veldhuis Kroeze, Koert Stittelaar, VJ Teeuwsen, Marcel Dijkshoorn, Geert Amerongen, L (Leon) van der Waal, Thijs Kuiken, Gabriel Krestin, J Hinkula, Ab Osterhaus

Research output: Contribution to journalArticleAcademicpeer-review

7 Citations (Scopus)

Abstract

Preclinical vaccine efficacy studies are generally limited to certain read out parameters such as assessment of virus titers in swabs and organs, clinical signs, serum antibody titers, and pathological changes. These parameters are not always routinely applied and not always scheduled in a logical standardized way. We used computed tomography (CT) imaging as additional and novel read out parameter in a vaccine efficacy study by quantifying alterations in aerated lung volumes in ferrets challenged with the 2009 pandemic A/H1N1 influenza virus. Vaccination protected from marked variations in aerated lung volumes compared to naive controls. The vaccinated group showed a daily gradual mean reduction with a maximum of 7.8%, whereas the controls showed a maximum of 143% reduction. The pulmonary opacities evident on CT images were most pronounced in the placebo-treated controls, and corresponded to significantly increased relative lung weights at necropsy. This study shows that consecutive in vivo CT imaging allows for a day to day read out of vaccine efficacy by quantification of altered aerated lung volumes. (C) 2012 Elsevier Ltd. All rights reserved.
Original languageUndefined/Unknown
Pages (from-to)7391-7394
Number of pages4
JournalVaccine
Volume30
Issue number51
DOIs
Publication statusPublished - 2012