TY - JOUR
T1 - Detection of hepatitis E virus-specific immunoglobulin A in patients infected with hepatitis E virus genotype 1 or 3
AU - Herremans, M.
AU - Duizer, E.
AU - Jusic, E.
AU - Koopmans, M. P.G.
PY - 2007/3
Y1 - 2007/3
N2 - Currently, diagnosis of acute hepatitis E virus (HEV) in patients is primarily based on anti-HEV immunoglobulin M (IgM) detection. However, several investigations suggest the use of HEV-specific IgA for diagnosing acute HEV infections. We evaluated two commercially available assays, an IgA enzyme-linked immunosorbent assay (ELISA) (Diacheck) and an adapted immunoblot protocol (Mikrogen) for IgA detection and compared the performance in genotype 1- and 3-infected patients. The specificity of the IgA assays was high, with no positive reactions in a control group of 18 acute hepatitis patients who were negative for HEV. The sensitivity calculated in nine PCR-positive type 1-infected patients was 100% in both assays but was clearly lower in genotype 3-infected patients (n = 14), with sensitivities of only 67% and 57% for the ELISA and immunoblot assay, respectively. The lower IgA responses detected in genotype 3-infected patients could be caused by the use of only the genotype 1 and 2 antigens in the serological assays. Interestingly in two patients with possible infection through blood transfusion no response or intermediate IgA responses were detected, and this might confirm the parenteral route of transmission. In both the type 1- and type 3-infected patients both the IgA and IgM responses disappeared simultaneously. We conclude that IgA detection is of limited value for the serodiagnosis of acute HEV cases, particularly with genotype 3.
AB - Currently, diagnosis of acute hepatitis E virus (HEV) in patients is primarily based on anti-HEV immunoglobulin M (IgM) detection. However, several investigations suggest the use of HEV-specific IgA for diagnosing acute HEV infections. We evaluated two commercially available assays, an IgA enzyme-linked immunosorbent assay (ELISA) (Diacheck) and an adapted immunoblot protocol (Mikrogen) for IgA detection and compared the performance in genotype 1- and 3-infected patients. The specificity of the IgA assays was high, with no positive reactions in a control group of 18 acute hepatitis patients who were negative for HEV. The sensitivity calculated in nine PCR-positive type 1-infected patients was 100% in both assays but was clearly lower in genotype 3-infected patients (n = 14), with sensitivities of only 67% and 57% for the ELISA and immunoblot assay, respectively. The lower IgA responses detected in genotype 3-infected patients could be caused by the use of only the genotype 1 and 2 antigens in the serological assays. Interestingly in two patients with possible infection through blood transfusion no response or intermediate IgA responses were detected, and this might confirm the parenteral route of transmission. In both the type 1- and type 3-infected patients both the IgA and IgM responses disappeared simultaneously. We conclude that IgA detection is of limited value for the serodiagnosis of acute HEV cases, particularly with genotype 3.
UR - http://www.scopus.com/inward/record.url?scp=34147145864&partnerID=8YFLogxK
U2 - 10.1128/CVI.00312-06
DO - 10.1128/CVI.00312-06
M3 - Article
C2 - 17267585
AN - SCOPUS:34147145864
SN - 1556-6811
VL - 14
SP - 276
EP - 280
JO - Clinical and Vaccine Immunology
JF - Clinical and Vaccine Immunology
IS - 3
ER -