Development of an enzyme-linked immune sorbent assay to measure nivolumab and pembrolizumab serum concentrations

Edwin Basak*, Annemarie Wijkhuijs, Ron Mathijssen, Stijn Koolen, Marco Schreurs

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

15 Citations (Scopus)

Abstract

Background: Treatment with monoclonal antibodies (mAbs) against programmed cell death protein 1 receptor is subject to high variation in treatment outcome among cancer patients. For these agents, no exposure–response (ER) relationships have been investigated in routine health care settings. However, ER relationships have been identified for several other mAbs used in oncology. Methods to conveniently measure serum concentrations of anti–programmed cell death protein 1 mAbs in routine health care may clarify possible ER relationships. Therefore, the authors aimed to develop an enzyme-linked immune sorbent assay (ELISA) for the measurement of both nivolumab and pembrolizumab serum concentrations of treated cancer patients. Methods: Optimal capture antigen and detection antibody concentrations were selected based on titrations. Nivolumab calibration standards ranging from 0.2 to 300 ng/mL were tested in duplicate. Accuracy was assessed in 2 recovery experiments. Intra- and interassay variations were assessed on 3 different days by 2 independent technicians. The developed ELISA was also set up for pembrolizumab calibration curves. Cross-reactivity of nivolumab measurements with ipilimumab was assessed. Of one nivolumab treated patient, serum concentrations in follow up samples were measured and presented. Results: Nivolumab calibration standards of 0.20–25 ng/mL were used. Nivolumab trough concentrations after 1 cycle in 8 patients ranged from 17.3 to 31.1 mcg/mL. The range of accuracy was 84%–105%, whereas intra- and interassay variations showed a coefficient of variation of 5.5% and 10.1%, respectively. No cross-reactivity with ipilimumab was detected. Pembrolizumab trough concentrations (n = 8) ranged from 9.1 to 19.7 mcg/mL after 1 infusion. Conclusions: The in-house–developed ELISA provides the opportunity to measure both nivolumab and pembrolizumab serum concentrations. This may help identify possible ER relationships in treated cancer patients and may potentially lead to dose adjustments in the future.

Original languageEnglish
Pages (from-to)596-601
Number of pages6
JournalTherapeutic Drug Monitoring
Volume40
Issue number5
DOIs
Publication statusPublished - 2018

Bibliographical note

Publisher Copyright:
Copyright © 2018 Wolters Kluwer Health, Inc. All rights reserved.

Research programs

  • EMC MM-02-72-02
  • EMC MM-03-86-08

Fingerprint

Dive into the research topics of 'Development of an enzyme-linked immune sorbent assay to measure nivolumab and pembrolizumab serum concentrations'. Together they form a unique fingerprint.

Cite this