Skip to main navigation Skip to search Skip to main content

Diagnostic Accuracy of Stool Tests for Colorectal Cancer Surveillance in Hodgkin Lymphoma Survivors

  • Berbel Ykema
  • , Lisanne Rigter
  • , Manon Spaander
  • , Leon Moons
  • , Tanya Bisseling
  • , Berthe Aleman
  • , Jean Paul de Boer
  • , Elly Lugtenburg
  • , Cecile Janus
  • , Eefke Petersen
  • , Judith Roesink
  • , John Raemaekers
  • , Richard van der Maazen
  • , Iris Lansdorp - Vogelaar
  • , Andrea Gini
  • , Wieke Verbeek
  • , Margriet Lemmens
  • , Gerrit Meijer
  • , Flora van Leeuwen
  • , Petur Snaebjornsson
  • Beatriz Carvalho, Monique van Leerdam
  • Netherlands Cancer Institute
  • University Medical Centre Utrecht

Research output: Contribution to journal › Article › Academic › peer-review

5 Citations (Scopus)
7 Downloads (Pure)

Abstract

Background: Hodgkin lymphoma (HL) survivors have an increased colorectal cancer (CRC) risk. Diagnostic accuracy of quantitative fecal immunochemical testing (FIT, OC Sensor) and/or a multi-target stool DNA test (mt-sDNA, Cologuard®) for advanced neoplasia (AN) was evaluated. Methods: 101 HL survivors underwent a surveillance colonoscopy and were asked to perform two stool tests (FIT and mt-sDNA). Advanced adenoma (AA), advanced serrated lesion (ASL), and AN (AA, ASL, CRC) were evaluated. Sensitivity, specificity, and area under the curve (AUC) for AN were calculated for different FIT cut-offs and mt-sDNA with colonoscopy as reference. Results: FIT and mt-sDNA were analyzed in 73 (72%) and 82 (81%) participants, respectively. AN was detected in 19 (26%) and 22 (27%), respectively. AN sensitivities for FIT cut-off of 10 ug Hb/g feces (FIT10) and mt-sDNA were 37% (95% confidence interval (CI): 16–62) and 68% (95% CI: 45–86), with corresponding specificities of 91% (95% CI: 80–97) and 70% (95% CI: 57–86), respectively. AUC for FIT was 0.68 (95% CI: 0.54–0.82) and for mt-sDNA 0.76 (95% CI: 0.63–0.89). Conclusions: In HL survivors, mt-sDNA showed highest sensitivity but with relatively low specificity for AN. Cost-effectiveness analyses is necessary to determine the optimal surveillance strategy.
Original languageEnglish
Article number190
JournalJournal of Clinical Medicine
Volume9
Issue number1
DOIs
Publication statusPublished - 10 Jan 2020

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Research programs

  • EMC MM-04-20-01
  • EMC NIHES-02-65-01

Fingerprint

Dive into the research topics of 'Diagnostic Accuracy of Stool Tests for Colorectal Cancer Surveillance in Hodgkin Lymphoma Survivors'. Together they form a unique fingerprint.

Cite this