Dose reduction in spiral CT coronary angiography with dual-source equipment. Part I. A phantom study applying different prospective tube current modulation algorithms

C Martini, AA Palumbo, E Maffei, Alexia Rossi, M Rengo, R Malago, Marcel Dijkshoorn, A.C. Weustink, Nico Mollet, Gabriel Krestin, F. Cademartiri

Research output: Contribution to journalArticleAcademic

7 Citations (Scopus)

Abstract

Purpose. The authors sought to compare different algorithms for dose reduction in retrospectively echocardiographically (ECG)-gated dual-source computed tomography (CT) coronary angiography (DSCT-CA) in a phantom model. Materials and methods. Weighted CT dose index (CTDI) was measured by using an anthropomorphic phantom in spiral cardiac mode (retrospective ECG gating) at five pitch values adapted with two heart-rate-adaptive ECG pulsing windows using four algorithms: narrow pulsing window, with tube current reduction to 20% (A) and 4% (B) of peak current outside the pulsing window; wide pulsing window, with tube current reduction to 20% (C) and 4% (D). Each algorithm was applied at different heart rates (45, 60, 75, 90, 120 bpm). Results. Mean CTDI volume (CTDIvol) was 36.9 +/- 9.7 mGy, 23.9 +/- 5.6 mGy, 49.7 +/- 16.2 mGy and 38.5 +/- 12.3 mGy for A. B. C and D, respectively. Consistent dose reduction was observed with protocols applying the 4% tube current reduction (B and D). Using the conversion coefficient for the chest, the mean effective dose was the highest for C (9.6 mSv) and the lowest for B (4.6 mSv). Heart-rate-dependent pitch values (pitch=0.2, 0.26, 0.34, 0.43, 0.5) and the use of heart-rate-adaptive ECG pulsing windows provided a significant decrease in the CTDIvol with progressively higher heart rates (45, 60, 75, 90, 120 bpm), despite using wider pulsing windows. Conclusions. Radiation exposure with DSCT-CA using a narrow pulsing window significantly decreases when compared with a wider pulsing window. When using a protocol with reduced tube current to 4%, the radiation dose is significantly lower.
Original languageUndefined/Unknown
Pages (from-to)1037-1052
Number of pages16
JournalRadiologia Medica
Volume114
Issue number7
DOIs
Publication statusPublished - 2009

Research programs

  • EMC COEUR-09
  • EMC NIHES-03-30-01

Cite this