Functional and radiographic outcomes of reverse shoulder arthroplasty with a minimum follow-up of 10 years

Thibault Lafosse, Arno A. Macken*, Geoffroi Lallemand, Giovanni Caruso, Geert A. Buijze, Laurent Lafosse

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

2 Citations (Scopus)
8 Downloads (Pure)

Abstract

Background: The use of reverse shoulder arthroplasty (RSA) is becoming increasingly prevalent. However, few studies have been published reporting the long-term outcomes of RSA. This study aims to report the clinical, radiographic, and patient-reported outcomes of the Delta Xtend reverse shoulder prosthesis, performed by a single surgeon and with a minimum follow-up of 10 years. Methods: All RSA procedures performed between 2005 and 2012 were identified. Patients were contacted and invited for a follow-up visit including clinical assessment, radiographs, and patient-reported outcome measures. Patients with a follow-up of less than 10 years were excluded. The revision-free implant survival was calculated at 10 years. Between 2005 and 2012, 119 procedures in 116 patients meeting inclusion criteria were identified. Of these patients, 35 were deceased before reaching the 10-year follow-up and 23 could not be reached. In total, 63 RSAs could be included in 61 patients (response rate: 75%). The median follow-up was 11.7 years (interquartile range [IQR]: 10.5-13.2). Results: Of the 61 patients, 7 patients underwent a revision after a median of 3 years (IQR: 0.2-9.8) during the total follow-up period. The 10-year implant survival was 94% (95% confidence interval: 84-98). At final follow-up, the median anterior elevation was 135° (IQR: 130°-160°), the median abduction was 120° (IQR: 100°-135°), and the median level reached with internal rotation was L5 (IQR: sacrum-L5). The median Auto-Constant score was 68 (IQR: 53-78), the median Subjective Shoulder Value was 80 (IQR: 70-93), and the median pain score was 0.2/10 (IQR: 0-2). In total, radiographs could be obtained in 25 patients (40%). Scapular notching occurred in 10 patients (40%), which was classified as Sirveaux-Nerot grade IV in 3 patients (12%). Ossification occurred in 10 patients (40%), and stress shielding in 2 patients (8%). Radiolucencies were observed around the humeral component in 24 patients (96%) and around the glenoid component in 13 patients (52%). Conclusion: The long-term results of RSA with a Delta Xtend prosthesis are favorable, with long-term improvement in range of motion and patient-reported outcome measures, and a satisfactory implant survival rate. Interestingly, the radiographical analysis showed high prevalence of signs associated with loosening, which did not seem to translate to high complication rates or inferior results.

Original languageEnglish
Pages (from-to)1313-1323
Number of pages11
JournalJournal of Shoulder and Elbow Surgery
Volume33
Issue number6
Early online date20 Oct 2023
DOIs
Publication statusPublished - Jun 2024

Bibliographical note

Publisher Copyright: © 2023 The Author(s)

Fingerprint

Dive into the research topics of 'Functional and radiographic outcomes of reverse shoulder arthroplasty with a minimum follow-up of 10 years'. Together they form a unique fingerprint.

Cite this