Skip to main navigation Skip to search Skip to main content

Functional Gaps and Atrial Fibrosis as Predictors of Early Arrhythmia Recurrence After Robotic-Enhanced Hybrid Ablation for Persistent Atrial Fibrillation

  • Eduardo Celentano
  • , Ernesto Cristiano*
  • , Erika Bertella
  • , Matteo Parrinello
  • , Giovanni Albano
  • , Barbara Ignatiuk
  • , Martina Renda
  • , Elena Bia
  • , Anthea d'Amico
  • , Raffaele Rainone
  • , Ascanio Graniero
  • , Laura Giroletti
  • , Laura Polini
  • , Mario Gasparri
  • , Stefano Schena
  • , Alfonso Agnino
  • , Natasja M. S. De Groot
  • *Corresponding author for this work
  • Istituto Clinico Humanitas Gavazzeni
  • University of Bergamo
  • Medical College of Wisconsin

Research output: Contribution to journal › Article › Academic › peer-review

2 Citations (Scopus)
13 Downloads (Pure)

Abstract

Background Robotic-enhanced hybrid ablation (RE-HA) is a promising strategy for persistent (PsAF) and long-standing persistent atrial fibrillation (LS-PsAF). The impact of post-epicardial conduction gaps and atrial fibrosis on early arrhythmia recurrence (EAR) is unclear.
Objective To assess whether conduction gaps and atrial fibrosis predict EAR within 3 months after the epicardial stage of RE-HA.
Methods Forty-two PsAF/LS-PsAF patients underwent RE-HA with left atrial appendage closure. High-density endocardial mapping at 3 months identified fixed (present in all maps) and functional (present in >= 1 but not all maps) conduction gaps. Atrial fibrosis was quantified by pre-procedural cardiac magnetic resonance (CMR).
Results Gaps were found in 18 patients (42.3%): functional in 10 (23.8%) and fixed in 13 (31.0%), with 5 (12%) showing both. EAR occurred in 12 patients (28.6%), AFL in 10/12 (83.3%). Gaps predicted AFL (OR 4.56; p = 0.003) and EAR (OR 3.50; p = 0.005). Left atrium LGE >= 10% independently predicted EAR (OR 7.50; p = 0.019) with no interaction with gap presence (p = 0.24). Total RF time was similar between groups despite more gaps in recurrence cases, reflecting procedural factors beyond gap count. Roof-line gaps predominated and colocalized with epicardial fat on CMR.
Conclusion Delayed high-density mapping after RE-HA reveals fixed and functional conduction gaps, especially at the roof line, that-together with pre-ablation fibrosis-independently predict EAR. These findings highlight distinct anatomical and electrophysiological risk domains and support substrate assessment with targeted endocardial completion in a staged workflow.
Original languageEnglish
Pages (from-to)3173-3183
Number of pages11
JournalJournal of Cardiovascular Electrophysiology
Volume36
Issue number12
Early online date29 Sept 2025
DOIs
Publication statusPublished - Dec 2025

Bibliographical note

Publisher Copyright:
© 2025 Wiley Periodicals LLC.

Fingerprint

Dive into the research topics of 'Functional Gaps and Atrial Fibrosis as Predictors of Early Arrhythmia Recurrence After Robotic-Enhanced Hybrid Ablation for Persistent Atrial Fibrillation'. Together they form a unique fingerprint.

Cite this