Skip to main navigation Skip to search Skip to main content

ICG-Fluorescence Imaging for Margin Assessment during Minimally Invasive Colorectal Liver Metastasis Resection

  • Friso B. Achterberg
  • , Okker D. Bijlstra
  • , Maxime D. Slooter
  • , Babs G. Sibinga Mulder
  • , Mark C. Boonstra
  • , Stefan A. Bouwense
  • , Koop Bosscha
  • , Mariëlle M.E. Coolsen
  • , Wouter J.M. Derksen
  • , Michael F. Gerhards
  • , Paul D. Gobardhan
  • , Jeroen Hagendoorn
  • , Daan Lips
  • , Hendrik A. Marsman
  • , Babs M. Zonderhuis
  • , Lissa Wullaert
  • , Hein Putter
  • , Jacobus Burggraaf
  • , J. Sven D. Mieog
  • , Alexander L. Vahrmeijer
  • Rutger Jan Swijnenburg*
*Corresponding author for this work
  • Leiden University
  • Amsterdam UMC
  • Maastricht University
  • Jeroen Bosch Ziekenhuis
  • St. Antonius Ziekenhuis
  • Onze Lieve Vrouwe Gasthuis
  • Amphia Hospital
  • Utrecht University
  • Medisch Spectrum Twente
  • Amphia Ziekenhuis
  • Center for Human Drug Research
  • Leiden University Medical Centre

Research output: Contribution to journal › Article › Academic › peer-review

60 Citations (Scopus)
59 Downloads (Pure)

Abstract

Importance: 

Unintended tumor-positive resection margins occur frequently during minimally invasive surgery for colorectal liver metastases and potentially negatively influence oncologic outcomes. 

Objective: 

To assess whether indocyanine green (ICG)-fluorescence-guided surgery is associated with achieving a higher radical resection rate in minimally invasive colorectal liver metastasis surgery and to assess the accuracy of ICG fluorescence for predicting the resection margin status. 

Design, Setting, and Participants: 

The MIMIC (Minimally Invasive, Indocyanine-Guided Metastasectomy in Patients With Colorectal Liver Metastases) trial was designed as a prospective single-arm multicenter cohort study in 8 Dutch liver surgery centers. Patients were scheduled to undergo minimally invasive (laparoscopic or robot-assisted) resections of colorectal liver metastases between September 1, 2018, and June 30, 2021. 

Exposures: 

All patients received a single intravenous bolus of 10 mg of ICG 24 hours prior to surgery. During surgery, ICG-fluorescence imaging was used as an adjunct to ultrasonography and regular laparoscopy to guide and assess the resection margin in real time. The ICG-fluorescence imaging was performed during and after liver parenchymal transection to enable real-time assessment of the tumor margin. Absence of ICG fluorescence was favorable both during transection and in the tumor bed directly after resection. 

Main Outcomes and Measures: 

The primary outcome measure was the radical (R0) resection rate, defined by the percentage of colorectal liver metastases resected with at least a 1 mm distance between the tumor and resection plane. Secondary outcomes were the accuracy of ICG fluorescence in detecting margin-positive (R1; <1 mm margin) resections and the change in surgical management. 

Results:

 In total, 225 patients were enrolled, of whom 201 (116 [57.7%] male; median age, 65 [IQR, 57-72] years) with 316 histologically proven colorectal liver metastases were included in the final analysis. The overall R0 resection rate was 92.4%. Re-resection of ICG-fluorescent tissue in the resection cavity was associated with a 5.0% increase in the R0 percentage (from 87.4% to 92.4%; P <.001). The sensitivity and specificity for real-time resection margin assessment were 60% and 90%, respectively (area under the receiver operating characteristic curve, 0.751; 95% CI, 0.668-0.833), with a positive predictive value of 54% and a negative predictive value of 92%. After training and proctoring of the first procedures, participating centers that were new to the technique had a comparable false-positive rate for predicting R1 resections during the first 10 procedures (odds ratio, 1.36; 95% CI, 0.44-4.24). The ICG-fluorescence imaging was associated with changes in intraoperative surgical management in 56 (27.9%) of the patients. 

Conclusions and Relevance: 

In this multicenter prospective cohort study, ICG-fluorescence imaging was associated with an increased rate of tumor margin-negative resection and changes in surgical management in more than one-quarter of the patients. The absence of ICG fluorescence during liver parenchymal transection predicted an R0 resection with 92% accuracy. These results suggest that use of ICG fluorescence may provide real-time feedback of the tumor margin and a higher rate of complete oncologic resection.

Original languageEnglish
Article numberE246548
JournalJAMA network open
Volume7
Issue number4
DOIs
Publication statusPublished - 19 Apr 2024

Bibliographical note

Publisher Copyright:
© 2024 American Medical Association. All rights reserved.

Fingerprint

Dive into the research topics of 'ICG-Fluorescence Imaging for Margin Assessment during Minimally Invasive Colorectal Liver Metastasis Resection'. Together they form a unique fingerprint.

Cite this