Impact of Measured and Predicted Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement

  • Henning Guthoff
  • , Mohamed Abdel-Wahab
  • , the IMPPACT TAVR Investigators
  • , Won Keun Kim
  • , Guy Witberg
  • , Hendrik Wienemann
  • , Maria Thurow
  • , Jasmin Shamekhi
  • , Clemens Eckel
  • , Ina von der Heide
  • , Verena Veulemans
  • , Martin Landt
  • , Marco Barbanti
  • , Ariel Finkelstein
  • , Jury Schewel
  • , Nicolas Van Mieghem
  • , Rik Adrichem
  • , Stefan Toggweiler
  • , Tobias Rheude
  • , Luis Nombela-Franco
  • Ignacio J. Amat-Santos, Philipp Ruile, Rodrigo Estévez-Loureiro, Matjaz Bunc, Luca Branca, Ole De Backer, Giuseppe Tarantini, Darren Mylotte, Dabit Arzamendi, Markus Pauly, Sabine Bleiziffer, Matthias Renker, Baravan Al-Kassou, Helge Möllmann, Sebastian Ludwig, Tobias Zeus, Corrado Tamburino, Tobias Schmidt, Andreas Rück, Philipp von Stein, Holger Thiele, Ahmed Abdelhafez, Matti Adam, Stephan Baldus, Tanja Rudolph, Victor Mauri*
*Corresponding author for this work
  • University of Cologne
  • Fresenius AG
  • Kerckhoff Heart Center
  • Justus Liebig University Giessen
  • German Centre for Cardiovascular Research
  • Rabin Medical Center Israel
  • TU Dortmund University
  • University Hospital Bonn
  • St.-Johannes-Hospital Dortmund
  • University of Hamburg
  • Universitätsklinikum Düsseldorf
  • Segeberger Kliniken
  • Kore University of Enna
  • Tel Aviv Sourasky Medical Center
  • Marienkrankenhaus Hamburg
  • Asklepios Klinik St. Georg
  • Kantonsspital Luzern
  • Technical University of Munich
  • Hospital Clínico San Carlos de Madrid
  • Centro de Investigación Biomédica en Red (CIBER)
  • Hospital Clínico Universitario de Valladolid
  • University of Freiburg
  • Complejo Hospitalario Universitario
  • Ljubljanski Univerzitetni Klinicni Center
  • Brescia Civil Hospital
  • Rigshospitalet
  • University of Padua
  • Galway University Hospital
  • Hospital de La Santa Creu I Sant Pau
  • Ruhr University Bochum
  • University of Catania
  • Universitätsklinikum Schleswig-Holstein
  • Karolinska University Hospital
  • German Center for Neurodegenerative Diseases

Research output: Contribution to journalArticleAcademicpeer-review

14 Citations (Scopus)
294 Downloads (Pure)

Abstract

Background: 

Prosthesis-patient mismatch after transcatheter aortic valve replacement (TAVR) can be measured echocardiographically (measured prosthesis-patient mismatch [PPMm]) or predicted (predicted prosthesis-patient mismatch [PPMp]) using published effective orifice area (EOA) reference values. However, the clinical implications of PPM post-TAVR remain unclear. 

Objectives: 

This study aimed to elucidate the prevalence of PPMm and PPMp post-TAVR and their impact on mortality in a large international cohort. 

Methods: 

The IMPPACT TAVR (Impact of Measured or Predicted Prosthesis-pAtient mismatCh after TAVR) registry included 38,808 TAVR patients from 26 international centers. Valve Academic Research Consortium 3 criteria were used to define prosthesis-patient mismatch severity. EOA was determined echocardiographically (PPMm) or predicted (PPMp) based on core lab–derived EOA reference values. The primary endpoint was 2-year all-cause mortality. 

Results: 

The prevalence of PPMp (moderate: 6.8%, severe: 0.6%) was significantly lower than that of PPMm (moderate: 20.7%, severe: 4.3%; P < 0.001) with negligible correlation between the 2 methods (Kendall's tau c correlation coefficient: 0.063; P < 0.001). In unadjusted analyses, severe PPMm adversely influenced 2-year survival (HR: 1.22; 95% CI: 1.02-1.45; P = 0.027), whereas severe PPMp was not associated with outcomes (HR: 0.81; 95% CI: 0.55-1.19; P = 0.291). After adjusting for confounders, neither PPMm nor PPMp had a significant effect on 2-year all-cause mortality. 

Conclusions: 

PPMm and PPMp were associated with different patient characteristics, with PPMm tending toward worse (especially low flow) and PPMp toward better (especially women) survival. After adjusting for confounders, neither PPMm nor PPMp significantly affected 2-year all-cause mortality. Hence, valve selection should not solely be based on hemodynamics but rather on a holistic approach, including patient and procedural specifics.

Original languageEnglish
Pages (from-to)2626-2635
Number of pages10
JournalJACC: Cardiovascular Interventions
Volume17
Issue number22
DOIs
Publication statusPublished - 25 Nov 2024