Skip to main navigation Skip to search Skip to main content

Impact of overlapping newer generation drug-eluting stents on clinical and angiographic outcomes: pooled analysis of five trials from the international Global RESOLUTE Program

  • V Farooq
  • , Pascal Vranckx
  • , L Mauri
  • , DE Cutlip
  • , J Belardi
  • , S Silber
  • , P Widimsky
  • , M de Leon
  • , S Windecker
  • , I Meredith
  • , M Negoita
  • , F van Leeuwen
  • , FJ Neumann
  • , AC Yeung
  • , Hector Garcia Garcia
  • , PWJC (Patrick) Serruys
  • External organisation

Research output: Contribution to journal › Article › Academic › peer-review

37 Citations (Scopus)

Abstract

Background Overlapping first generation sirolimus- and paclitaxel-eluting stents are associated with persistent inflammation, fibrin deposition and delayed endothelialisation in preclinical models, and adverse angiographic and clinical outcomes-including death and myocardial infarction (MI)-in clinical studies. Objectives To establish as to whether there are any safety concerns with newer generation drug-eluting stents (DES). Design Propensity score adjustment of baseline anatomical and clinical characteristics were used to compare clinical outcomes (Kaplan-Meier estimates) between patients implanted with overlapping DES (Resolute zotarolimus-eluting stent (R-ZES) or R-ZES/other DES) against no overlapping DES. Additionally, angiographic outcomes for overlapping R-ZES and everolimus-eluting stents were evaluated in the randomised RESOLUTE All-Comers Trial. Setting Patient level data from five controlled studies of the RESOLUTE Global Clinical Program evaluating the R-ZES were pooled. Enrolment criteria were generally unrestrictive. Patients 5130 patients. Main outcome measures 2-year clinical outcomes and 13-month angiographic outcomes. Results 644 of 5130 patients (12.6%) in the RESOLUTE Global Clinical Program underwent overlapping DES implantation. Implantation of overlapping DES was associated with an increased frequency of MI and more complex/calcified lesion types at baseline. Adjusted in-hospital, 30-day and 2-year clinical outcomes indicated comparable cardiac death (2-year overlap vs non-overlap: 3.0% vs 2.1%, p=0.36), major adverse cardiac events (13.3% vs 10.7%, p=0.19), target-vessel MI (3.9% vs 3.4%, p=0.40), clini Conclusions Overlapping newer generation DES are safe and effective, with comparable angiographic and clinical outcomes-including repeat revascularisation-to non-overlapping DES.
Original languageUndefined/Unknown
Pages (from-to)626-633
Number of pages8
JournalHeart
Volume99
Issue number9
DOIs
Publication statusPublished - 2013

Research programs

  • EMC COEUR-09

Cite this