T1 - Interstitial Nd:YAG laser coagulation using simultaneous multiple fiber application with an optical beamsplitter
T2 - Lasers in Surgery: Advanced Characterization, Therapeutics, and Systems VII
AU - Heisterkamp, Joos
AU - Van Hillegersberg, Richard
AU - Sinofsky, Edward L.
AU - Ijzermans, Jan N.M.
PY - 1997/5/22
Y1 - 1997/5/22
N2 - In this study, the optimal combination of laser power and mutual fiber distance was assessed in order to take full advantage of simultaneous multiple fiber application in interstitial laser coagulation. For cylindrical diffusing fibers ((Theta) equals 600 micrometer, 2 cm diffusing length) were positioned in porcine liver tissue at a mutual distance of 1 - 4 cm. Nd:YAG laser light (lambda equals 1064 nm) of 4 - 7 W was guided through each fiber. By varying exposure time for the different power levels, energy applied was constant at 1800 J. The output of the four channels was measured with an output meter at various laser power levels with variation never exceeding 5%. After laser application the livers were sectioned and the zone of coagulation was measured in three directions; fusion between the coagulation zones surrounding the fibers was noted. Spherical lesions up to 5 cm (Theta) could be produced at the optimal settings of 7 W with a distance between the fibers of 2 cm. Mutual distances less than 2 cm resulted in smaller lesions with central carbonization and at larger distances no fusion between the four coagulative zones occurred.
AB - In this study, the optimal combination of laser power and mutual fiber distance was assessed in order to take full advantage of simultaneous multiple fiber application in interstitial laser coagulation. For cylindrical diffusing fibers ((Theta) equals 600 micrometer, 2 cm diffusing length) were positioned in porcine liver tissue at a mutual distance of 1 - 4 cm. Nd:YAG laser light (lambda equals 1064 nm) of 4 - 7 W was guided through each fiber. By varying exposure time for the different power levels, energy applied was constant at 1800 J. The output of the four channels was measured with an output meter at various laser power levels with variation never exceeding 5%. After laser application the livers were sectioned and the zone of coagulation was measured in three directions; fusion between the coagulation zones surrounding the fibers was noted. Spherical lesions up to 5 cm (Theta) could be produced at the optimal settings of 7 W with a distance between the fibers of 2 cm. Mutual distances less than 2 cm resulted in smaller lesions with central carbonization and at larger distances no fusion between the four coagulative zones occurred.
UR - https://www.scopus.com/pages/publications/58049164282
U2 - 10.1117/12.275086
DO - 10.1117/12.275086
M3 - Conference article
AN - SCOPUS:58049164282
SN - 0277-786X
VL - 2970
SP - 522
EP - 525
JO - Proceedings of SPIE - The International Society for Optical Engineering
JF - Proceedings of SPIE - The International Society for Optical Engineering
Y2 - 8 February 1997 through 8 February 1997
ER -