Skip to main navigation Skip to search Skip to main content

Liver contrrast-enhanced ultrasound improves detection of liver metastases in patients with pancreatic or periampullary cancer

Research output: Contribution to journalArticleAcademicpeer-review

9 Citations (Scopus)

Abstract

The aim of this study is to provide a diagnostic performance evaluation of contrast-enhanced ultrasonography (CEUS) in detecting liver metastases in patients with suspected of pancreatic or periampullary cancer. Computed tomography (CT) is often insufficient for detection of liver metastases, but their presence plays a crucial role in the choice of therapy. Eighty-nine patients with suspected pancreatic or periampullary cancer were included in this prospective study with retrospective analysis. Patients underwent an abdominal CT and CEUS. Fifteen patients had liver metastases. The CT sensitivity was 73.3% (11/15), the specificity 93.2% (69/74), the positive predictive value (PPV) 68.8% (11/16) and the negative predictive value (NPV) 94.6% (69/73). Based on CEUS, the sensitivity was 80% (12/15), specificity 98.6% (73/74), PPV 92.3% (12/13) and NPV 96.1% (73/76). CEUS improved characterization of liver lesions in patients with suspected pancreatic or periampullary cancer compared with CT. CEUS can better detect benign liver lesions and distinguish false-positive or indeterminate CT results. (C) 2015 World Federation for Ultrasound in Medicine & Biology.
Original languageUndefined/Unknown
Pages (from-to)3063-3069
Number of pages7
JournalUltrasound in Medicine and Biology
Volume41
Issue number12
DOIs
Publication statusPublished - 2015

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Research programs

  • EMC MM-04-20-02-A
  • EMC MM-04-47-07
  • EMC NIHES-03-30-01

Cite this