TY - JOUR
T1 - Long-term stabilized blood samples as controls for flow cytometric HLA-B27 screening: A feasibility study
AU - Levering, Wilfried
AU - Wind, Henk
AU - Granger, V
AU - Sintnicolaas, K
AU - Hooijkaas, H (Herbert)
AU - Reilly, JT
AU - Gratama, Jan willem
AU - Barnett, D
PY - 2008
Y1 - 2008
N2 - Background: Long-term stabilized blood samples are potentially useful as positive or negative procedure controls for flow cytometric HLA-B27 screening, and could serve as test samples in an external quality assessment (EQA) scheme. We evaluated long-term stabilized whole blood specimens as prepared for the UK NEQAS for Leucocyte Immunophenotyping EQA scheme (Sheffield, UK). Methods: Peripheral blood samples were obtained from nine blood bank donors with known HLA-B typing. Short-term stabilization with Trans-FIX(TM) was performed before shipment to Sheffield. Thereafter, long-term stabilization was performed. Commercially available HLA-B27 mAb were tested periodically between 1 week and 12 months on (i) fresh, (ii) short-term stabilized, and (iii) long-term stabilized blood samples using a stain, lyse, and wash technique. We compared the forward scatter (FSC), sideward scatter (SSC), and fluorescence signals of lymphocytes as a function of time. Furthermore, a pilot send-out with stabilized blood samples of four blood bank donors was distributed among the participants to the Benelux EQA scheme for HLA-B27 screening, and results were compared with historical EQA data obtained using nonstabilized blood samples from the same donors. Results: There were no major effects on FSC and SSC characteristics of lymphocytes. Background fluorescence of stabilized samples increased and specific fluorescence of stabilized HLA-B27 positive samples decreased as compared with fresh samples. However, discrimination between the investigated HLA-B27 positive and HLA-B27 negative samples remained feasible poststabilization. In the pilot send-out, the results obtained with stabilized samples were less concordant than with the corresponding fresh. samples due to variable quality of the stabilized samples. Conclusion: Long-term stabilized whole blood samples are potentially useful as true HLA-B27 positive and true HLA-B27 negative control cells for daily and longitudinal quality control of flow cytometric HLA-B27 screening. In the same way, long-term stabilized samples may be used for EQA purposes. However, these samples are currently not feasible for reagent validation purposes. Extensive quality control of long-term stabilized samples is necessary before distribution in multicenter surveys. (C) 2008 Clinical Cytometry Society.
AB - Background: Long-term stabilized blood samples are potentially useful as positive or negative procedure controls for flow cytometric HLA-B27 screening, and could serve as test samples in an external quality assessment (EQA) scheme. We evaluated long-term stabilized whole blood specimens as prepared for the UK NEQAS for Leucocyte Immunophenotyping EQA scheme (Sheffield, UK). Methods: Peripheral blood samples were obtained from nine blood bank donors with known HLA-B typing. Short-term stabilization with Trans-FIX(TM) was performed before shipment to Sheffield. Thereafter, long-term stabilization was performed. Commercially available HLA-B27 mAb were tested periodically between 1 week and 12 months on (i) fresh, (ii) short-term stabilized, and (iii) long-term stabilized blood samples using a stain, lyse, and wash technique. We compared the forward scatter (FSC), sideward scatter (SSC), and fluorescence signals of lymphocytes as a function of time. Furthermore, a pilot send-out with stabilized blood samples of four blood bank donors was distributed among the participants to the Benelux EQA scheme for HLA-B27 screening, and results were compared with historical EQA data obtained using nonstabilized blood samples from the same donors. Results: There were no major effects on FSC and SSC characteristics of lymphocytes. Background fluorescence of stabilized samples increased and specific fluorescence of stabilized HLA-B27 positive samples decreased as compared with fresh samples. However, discrimination between the investigated HLA-B27 positive and HLA-B27 negative samples remained feasible poststabilization. In the pilot send-out, the results obtained with stabilized samples were less concordant than with the corresponding fresh. samples due to variable quality of the stabilized samples. Conclusion: Long-term stabilized whole blood samples are potentially useful as true HLA-B27 positive and true HLA-B27 negative control cells for daily and longitudinal quality control of flow cytometric HLA-B27 screening. In the same way, long-term stabilized samples may be used for EQA purposes. However, these samples are currently not feasible for reagent validation purposes. Extensive quality control of long-term stabilized samples is necessary before distribution in multicenter surveys. (C) 2008 Clinical Cytometry Society.
U2 - 10.1002/cyto.b.20388
DO - 10.1002/cyto.b.20388
M3 - Article
VL - 74B
SP - 169
EP - 181
JO - Cytometry Part B - Clinical Cytometry
JF - Cytometry Part B - Clinical Cytometry
SN - 1552-4949
IS - 3
ER -