Long-term stabilized blood samples as controls for flow cytometric HLA-B27 screening: A feasibility study

Wilfried Levering, Henk Wind, V Granger, K Sintnicolaas, H (Herbert) Hooijkaas, JT Reilly, Jan willem Gratama, D Barnett

Research output: Contribution to journalArticleAcademicpeer-review

3 Citations (Scopus)

Abstract

Background: Long-term stabilized blood samples are potentially useful as positive or negative procedure controls for flow cytometric HLA-B27 screening, and could serve as test samples in an external quality assessment (EQA) scheme. We evaluated long-term stabilized whole blood specimens as prepared for the UK NEQAS for Leucocyte Immunophenotyping EQA scheme (Sheffield, UK). Methods: Peripheral blood samples were obtained from nine blood bank donors with known HLA-B typing. Short-term stabilization with Trans-FIX(TM) was performed before shipment to Sheffield. Thereafter, long-term stabilization was performed. Commercially available HLA-B27 mAb were tested periodically between 1 week and 12 months on (i) fresh, (ii) short-term stabilized, and (iii) long-term stabilized blood samples using a stain, lyse, and wash technique. We compared the forward scatter (FSC), sideward scatter (SSC), and fluorescence signals of lymphocytes as a function of time. Furthermore, a pilot send-out with stabilized blood samples of four blood bank donors was distributed among the participants to the Benelux EQA scheme for HLA-B27 screening, and results were compared with historical EQA data obtained using nonstabilized blood samples from the same donors. Results: There were no major effects on FSC and SSC characteristics of lymphocytes. Background fluorescence of stabilized samples increased and specific fluorescence of stabilized HLA-B27 positive samples decreased as compared with fresh samples. However, discrimination between the investigated HLA-B27 positive and HLA-B27 negative samples remained feasible poststabilization. In the pilot send-out, the results obtained with stabilized samples were less concordant than with the corresponding fresh. samples due to variable quality of the stabilized samples. Conclusion: Long-term stabilized whole blood samples are potentially useful as true HLA-B27 positive and true HLA-B27 negative control cells for daily and longitudinal quality control of flow cytometric HLA-B27 screening. In the same way, long-term stabilized samples may be used for EQA purposes. However, these samples are currently not feasible for reagent validation purposes. Extensive quality control of long-term stabilized samples is necessary before distribution in multicenter surveys. (C) 2008 Clinical Cytometry Society.
Original languageUndefined/Unknown
Pages (from-to)169-181
Number of pages13
JournalCytometry Part B-Clinical Cytometry
Volume74B
Issue number3
DOIs
Publication statusPublished - 2008

Cite this