TY - JOUR
T1 - Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA
T2 - Comparison of T1-weighted spin-echo and 3D gradient-echo sequences
AU - Li, Debiao
AU - Haacke, E. Mark
AU - Tarr, Robert W.
AU - Venkatesan, Ramesh
AU - Lin, Weili
AU - Wielopolski, Piotr
PY - 1996
Y1 - 1996
N2 - Short TR, short TE, high resolution, 3D gradient-recalled echo (GRE) imaging was evaluated for lesion detection in the brain. High resolution 3D GRE data acquisition was used to reduce partial volume effects and flow artifacts, to better visualize smaller structures, to minimize signal losses caused by field inhomogeneities, and to allow better image reformatting. Spin-echo (SE) and 3D GRE approaches were compared for lesion detection after the administration of an MR contrast agent, gadopentetate dimeglumine. Preliminary clinical studies demonstrated that the signal-to-noise ratio (SNR) in each slice of the GRE scan was worse than that of the SE scan because of the much thicker slices acquired with the SE technique. However, by averaging two adjacent 3D slices, the SNR of the two methods was essentially equivalent. In the averaged GRE slices, large lesions were seen just as well as in the SE images. More importantly, small lesions were better visualized in the thin 3D GRE images than in the thick SE images for the lesions studied in this work and the protocols used. These observations were confirmed by theoretical simulations.
AB - Short TR, short TE, high resolution, 3D gradient-recalled echo (GRE) imaging was evaluated for lesion detection in the brain. High resolution 3D GRE data acquisition was used to reduce partial volume effects and flow artifacts, to better visualize smaller structures, to minimize signal losses caused by field inhomogeneities, and to allow better image reformatting. Spin-echo (SE) and 3D GRE approaches were compared for lesion detection after the administration of an MR contrast agent, gadopentetate dimeglumine. Preliminary clinical studies demonstrated that the signal-to-noise ratio (SNR) in each slice of the GRE scan was worse than that of the SE scan because of the much thicker slices acquired with the SE technique. However, by averaging two adjacent 3D slices, the SNR of the two methods was essentially equivalent. In the averaged GRE slices, large lesions were seen just as well as in the SE images. More importantly, small lesions were better visualized in the thin 3D GRE images than in the thick SE images for the lesions studied in this work and the protocols used. These observations were confirmed by theoretical simulations.
UR - http://www.scopus.com/inward/record.url?scp=0030137094&partnerID=8YFLogxK
U2 - 10.1002/jmri.1880060302
DO - 10.1002/jmri.1880060302
M3 - Article
C2 - 8724406
AN - SCOPUS:0030137094
SN - 1053-1807
VL - 6
SP - 415
EP - 424
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 3
ER -