Multicenter Consistency Assessment of Valvular Flow Quantification With Automated Valve Tracking in 4D Flow CMR

  • Joe F. Juffermans*
  • , Savine C.S. Minderhoud
  • , Johan Wittgren
  • , Anton Kilburg
  • , Amir Ese
  • , Benjamin Fidock
  • , Yu Cong Zheng
  • , Jun Mei Zhang
  • , Carmen P.S. Blanken
  • , Hildo J. Lamb
  • , Jelle J. Goeman
  • , Marcus Carlsson
  • , Shihua Zhao
  • , R. Nils Planken
  • , Pim van Ooij
  • , Liang Zhong
  • , Xiuyu Chen
  • , Pankaj Garg
  • , Tilman Emrich
  • , Alexander Hirsch
  • Johannes Töger, Jos J.M. Westenberg
*Corresponding author for this work
  • Leiden University Medical Centre
  • Lund University
  • University Medical Center Mainz
  • University of Sheffield
  • Fuwai Hospital
  • National University of Singapore
  • Amsterdam UMC
  • Partner Site Munich

Research output: Contribution to journalArticleAcademicpeer-review

40 Citations (Scopus)

Abstract

Objectives: This study determined: 1) the interobserver agreement; 2) valvular flow variation; and 3) which variables independently predicted the variation of valvular flow quantification from 4-dimensional (4D) flow cardiac magnetic resonance (CMR) with automated retrospective valve tracking at multiple sites. Background: Automated retrospective valve tracking in 4D flow CMR allows consistent assessment of valvular flow through all intracardiac valves. However, due to the variance of CMR scanners and protocols, it remains uncertain if the published consistency holds for other clinical centers. Methods: Seven sites each retrospectively or prospectively selected 20 subjects who underwent whole heart 4D flow CMR (64 patients and 76 healthy volunteers; aged 32 years [range 24 to 48 years], 47% men, from 2014 to 2020), which was acquired with locally used CMR scanners (scanners from 3 vendors; 2 1.5-T and 5 3-T scanners) and protocols. Automated retrospective valve tracking was locally performed at each site to quantify the valvular flow and repeated by 1 central site. Interobserver agreement was evaluated with intraclass correlation coefficients (ICCs). Net forward volume (NFV) consistency among the valves was evaluated by calculating the intervalvular variation. Multiple regression analysis was performed to assess the predicting effect of local CMR scanners and protocols on the intervalvular inconsistency. Results: The interobserver analysis demonstrated strong-to-excellent agreement for NFV (ICC: 0.85 to 0.96) and moderate-to-excellent agreement for regurgitation fraction (ICC: 0.53 to 0.97) for all sites and valves. In addition, all observers established a low intervalvular variation (≤10.5%) in their analysis. The availability of 2 cine images per valve for valve tracking compared with 1 cine image predicted a decreasing variation in NFV among the 4 valves (beta = −1.3; p = 0.01). Conclusions: Independently of locally used CMR scanners and protocols, valvular flow quantification can be performed consistently with automated retrospective valve tracking in 4D flow CMR.

Original languageEnglish
Pages (from-to)1354-1366
Number of pages13
JournalJACC: Cardiovascular Imaging
Volume14
Issue number7
DOIs
Publication statusPublished - Jul 2021

Bibliographical note

Funding Information:
Drs. Zhang and Zhong were supported by the National Medical Research Council (NMRC/OFIRG/0018/2016; NMRC/BnB/0017/2015; MOH-000358; MOH-000351) and SingHealth Duke-NUS Academic Medicine Research Grants (AM/TP015/2018 (SRDUKAMR1814); AM/TP032/2020 (SRDUKAMR2032). All other authors have reported that they have no relationships relevant to the content of this paper to disclose.