TY - JOUR
T1 - Oscillometry and applanation tonometry measurements in older individuals with elevated levels of arterial stiffness
AU - Boon - van Dijk, Suzanne
AU - Enneman, Anke
AU - Swart, KMA
AU - Schoor, NM
AU - Uitterlinden, André
AU - Smulders, YM
AU - van den Meiracker, Ton
AU - van der Velde, Nathalie
AU - Mattace Raso, F.U.S.
PY - 2013
Y1 - 2013
N2 - ObjectiveIndices of arterial stiffness and aortic pressure are usually assessed by applanation tonometry. The more recently introduced oscillometric device is simpler to use. Several studies have investigated the agreement between these two devices, but not in populations with elevated levels of arterial stiffness. Therefore, we evaluated the agreement in an elderly population with high risk of arterial stiffness. Patients and methodsWe included a subgroup of the B-PROOF study (n=344, mean age 73 years, 60% men), whose aortic pulse wave velocity (aPWV), aortic augmentation index (AIx), aortic pulse pressure (PP), and aortic systolic blood pressure (SBP) were assessed both with applanation tonometry (SphygmoCor) and with oscillometry (Arteriograph). We investigated agreement between the two devices using Pearson correlations and Bland-Altman analysis. We carried out a stratified analysis in participants wi ResultsThe oscillometric method produced higher values of AIx, aortic PP, and aortic SBP (P<0.01) than applanation tonometry. aPWV values were lower (P<0.01) and were not correlated (r=-0.06, P=0.92), whereas AIx measurements (r=0.35 P<0.01), aortic PP (r=0.57 P<0.01), and aortic SBP (r=0.68 P<0.01) measurements were correlated. Bland-Altman analysis showed insufficient agreement between the two devices, especially in those with elevated levels of arterial stiffness (aPWV>12 m/s). ConclusionParticularly in the elderly with elevated levels of arterial stiffness, measurements of aPWV obtained with oscillometry and applanation tonometry show poor agreement. Also, AIx, aortic SBP, and aortic PP show clearly less than optimal agreement.
AB - ObjectiveIndices of arterial stiffness and aortic pressure are usually assessed by applanation tonometry. The more recently introduced oscillometric device is simpler to use. Several studies have investigated the agreement between these two devices, but not in populations with elevated levels of arterial stiffness. Therefore, we evaluated the agreement in an elderly population with high risk of arterial stiffness. Patients and methodsWe included a subgroup of the B-PROOF study (n=344, mean age 73 years, 60% men), whose aortic pulse wave velocity (aPWV), aortic augmentation index (AIx), aortic pulse pressure (PP), and aortic systolic blood pressure (SBP) were assessed both with applanation tonometry (SphygmoCor) and with oscillometry (Arteriograph). We investigated agreement between the two devices using Pearson correlations and Bland-Altman analysis. We carried out a stratified analysis in participants wi ResultsThe oscillometric method produced higher values of AIx, aortic PP, and aortic SBP (P<0.01) than applanation tonometry. aPWV values were lower (P<0.01) and were not correlated (r=-0.06, P=0.92), whereas AIx measurements (r=0.35 P<0.01), aortic PP (r=0.57 P<0.01), and aortic SBP (r=0.68 P<0.01) measurements were correlated. Bland-Altman analysis showed insufficient agreement between the two devices, especially in those with elevated levels of arterial stiffness (aPWV>12 m/s). ConclusionParticularly in the elderly with elevated levels of arterial stiffness, measurements of aPWV obtained with oscillometry and applanation tonometry show poor agreement. Also, AIx, aortic SBP, and aortic PP show clearly less than optimal agreement.
U2 - 10.1097/MBP.0000000000000009
DO - 10.1097/MBP.0000000000000009
M3 - Article
C2 - 24192847
SN - 1359-5237
VL - 18
SP - 332
EP - 338
JO - Blood Pressure Monitoring
JF - Blood Pressure Monitoring
IS - 6
ER -