T1 - Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System
AU - van der Boon, Robert
AU - van Mieghem, Nicolas
AU - Theuns, Dominic
AU - Nuis, Rutger-jan
AU - Nauta, Sjoerd
AU - Serruys, PWJC (Patrick)
AU - Jordaens, Luc
AU - van Domburg, Ron
AU - de Jaegere, Peter
PY - 2013
Y1 - 2013
N2 - Background/objectives: To determine pacemaker (PM) dependency at follow-up visit in patients who underwent new permanent pacemaker implantation (PPI) following transcatheter aortic valve implantation (TAVI). Methods: Single center prospective observational study including 167 patients without previous PM implantation who underwent TAVI with the self-expanding Medtronic CoreValve System (MCS) between November 2005 and February 2011. PM dependency was defined by the presence of a high degree atrioventricular block (HDAVB; second [AV2] and third degree [AV3B]), or a slow (<30 bpm) or absent ventricular escape rhythm during follow-up PM interrogation. Results: A total of 36 patients (21.6%) received a new PM following TAVI. The indication for PM was AV2B (n=2, 5.6%), AV3B (n=28, 77.8%), postoperative symptomatic bradycardia (n=3, 8.3%), brady-tachy syndrome (n=1, 2.8%), atrial fibrilation with slow response (n=1, 2.8%) and left bundle branch block (n=1, 2.8%). Long term follow-up was complete for all patients and ranged from 1 to 40 months (median (IQR): 11.5 (5.0-18.0 months). Of those patients with a HDAVB, 16 out of the 30 patients (53.3%) Conclusion: Partial and even complete resolution of peri-operative AV conduction abnormalities after MCS valve implantation occurred in more than half of the patients. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
AB - Background/objectives: To determine pacemaker (PM) dependency at follow-up visit in patients who underwent new permanent pacemaker implantation (PPI) following transcatheter aortic valve implantation (TAVI). Methods: Single center prospective observational study including 167 patients without previous PM implantation who underwent TAVI with the self-expanding Medtronic CoreValve System (MCS) between November 2005 and February 2011. PM dependency was defined by the presence of a high degree atrioventricular block (HDAVB; second [AV2] and third degree [AV3B]), or a slow (<30 bpm) or absent ventricular escape rhythm during follow-up PM interrogation. Results: A total of 36 patients (21.6%) received a new PM following TAVI. The indication for PM was AV2B (n=2, 5.6%), AV3B (n=28, 77.8%), postoperative symptomatic bradycardia (n=3, 8.3%), brady-tachy syndrome (n=1, 2.8%), atrial fibrilation with slow response (n=1, 2.8%) and left bundle branch block (n=1, 2.8%). Long term follow-up was complete for all patients and ranged from 1 to 40 months (median (IQR): 11.5 (5.0-18.0 months). Of those patients with a HDAVB, 16 out of the 30 patients (53.3%) Conclusion: Partial and even complete resolution of peri-operative AV conduction abnormalities after MCS valve implantation occurred in more than half of the patients. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
U2 - 10.1016/j.ijcard.2012.11.115
DO - 10.1016/j.ijcard.2012.11.115
M3 - Article
SN - 0167-5273
VL - 168
SP - 1269
EP - 1273
JO - International Journal of Cardiology
JF - International Journal of Cardiology
IS - 2
ER -