Skip to main navigation Skip to search Skip to main content

PEEP-FiO2 table versus EIT to titrate PEEP in mechanically ventilated patients with COVID-19-related ARDS

Research output: Contribution to journal › Article › Academic › peer-review

33 Citations (Scopus)
77 Downloads (Pure)

Abstract

Rationale It is unknown how to titrate positive end-expiratory pressure (PEEP) in patients with COVID-19-related acute respiratory distress syndrome (ARDS). Guidelines recommend the one-size-fits-all PEEP-FiO2 table. In this retrospective cohort study, an electrical impedance tomography (EIT)-guided PEEP trial was used to titrate PEEP.

Objectives To compare baseline PEEP according to the high PEEP-FiO2 table and personalized PEEP following an EIT-guided PEEP trial.

Methods We performed an EIT-guided decremental PEEP trial in patients with moderate-to-severe COVID-19-related ARDS upon intensive care unit admission. PEEP was set at the lowest PEEP above the intersection of curves representing relative alveolar overdistention and collapse. Baseline PEEP was compared with PEEP set according to EIT. We identified patients in whom the EIT-guided PEEP trial resulted in a decrease or increase in PEEP of ≥ 2 cmH2O.

Measurements and main results We performed a PEEP trial in 75 patients. In 23 (31%) patients, PEEP was decreased ≥ 2 cmH2O, and in 24 (32%) patients, PEEP was increased ≥ 2 cmH2O. Patients in whom PEEP was decreased had improved respiratory mechanics and more overdistention in the non-dependent lung region at higher PEEP levels. These patients also had a lower BMI, longer time between onset of symptoms and intubation, and higher incidence of pulmonary embolism. Oxygenation improved in patients in whom PEEP was increased.

Conclusions An EIT-guided PEEP trial resulted in a relevant change in PEEP in 63% of patients. These results support the hypothesis that PEEP should be personalized in patients with ARDS.

Original languageEnglish
Article number272
Pages (from-to)272
Number of pages10
JournalCritical Care
Volume26
Issue number1
DOIs
Publication statusPublished - Dec 2022

Bibliographical note

Funding Information:
This study was entirely funded by the Department of Adult Intensive Care of the Erasmus Medical Center, Rotterdam, The Netherlands.

Publisher Copyright:
© 2022, The Author(s).

Fingerprint

Dive into the research topics of 'PEEP-FiO2 table versus EIT to titrate PEEP in mechanically ventilated patients with COVID-19-related ARDS'. Together they form a unique fingerprint.

Cite this