Objective:
A dynamic model is developed to predict the impact of radiotherapy on circulating lymphocyte counts in women with locally advanced cervical cancer (LACC). This study aims to compare the effects of photon and proton therapy, as well as the influence of bone marrow sparing (BMS) techniques, on relative lymphocyte preservation over time.
Approach:
A dynamic lymphocyte flow model was developed to simulate the migration of lymphocytes based on seven compartments. Biological cell death and lymphocyte production were integrated across compartments. The lymphocyte flow model was applied to 19 LACC patients. Volumetric modulated arc therapy (VMAT) and intensity modulated proton therapy (IMPT) treatment plans were created for each patient without BMS and with BMS. The model calculated radiation dose to lymphocytes to estimate radiation-induced cell death over time. The output of the model was the relative lymphocyte count relative to baseline (RLC) over time and the RLC nadir in the blood and total body.
Main results:
According to the model, IMPT resulted in lower doses to lymphocyte and higher RLC nadirs compared to VMAT for all 19 patients. The total RLC nadir (mean ± SD) was 48.4% ± 4.0% for VMAT and 62.5% ± 5.1% for IMPT. In the blood compartment, the RLC nadir was 32.7% ± 3.5% for VMAT and 47.7% ± 5.9% for IMPT. The RLC nadir in the blood compartment improved with 3Gy BMS from 32.7% ± 3.5% to 33.0% ± 3.5% , while it decreased for IMPT from 47.7% ± 5.9% to 46.6% ± 6.0%. Total RLC nadir decreased with BMS for VMAT from 48.4% ± 4.0% to 48.2% ± 3.9% and for IMPT from 62.5% ± 5.1% to 60.9% ± 5.3%.
Significance:
By incorporating a dynamic flow model, we predicted the RLC over time. The model predicted a substantial sparing effect IMPT has on the lymphocytes compared to VMAT. This sparing was both present in the blood and the total body. Sparing the bone marrow showed only a minimal effect on the RLC.
| Original language | English |
|---|---|
| Article number | 215005 |
| Journal | Physics in Medicine and Biology |
| Volume | 70 |
| Issue number | 21 |
| DOIs | |
| Publication status | Published - 22 Oct 2025 |
Bibliographical note
Publisher Copyright:© 2025 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd.
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Fingerprint
Dive into the research topics of 'Predicting lymphocyte dose and surviving fraction for VMAT and IMPT treatments with a dynamic lymphocyte flow model for locally advanced cervical cancer'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver