T1 - Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation With the Medtronic CoreValve System in Patients With Aortic Stenosis
AU - Tzikas, Apostolos
AU - Piazza, Nick
AU - Geleijnse, Marcel
AU - van Mieghem, Nicolas
AU - Nuis, Rutger-jan
AU - Schultz, Carl
AU - van Geuns, Robert Jan
AU - Galema, Tjebbe
AU - Kappetein, Arie-Pieter
AU - Serruys, PWJC (Patrick)
AU - de Jaegere, Peter
PY - 2010
Y1 - 2010
N2 - A prosthesis patient mismatch (PPM) is present when the prosthetic valve is too small in relation to the patient's body size. The purpose of the present study was to investigate the frequency of PPM after the implantation of the Medtronic Core Valve System, and its relation to the clinical outcome. The indexed effective orifice area (EOA) was measured in 74 patients with symptomatic severe aortic stenosis, who had undergone successful transcatheter aortic valve implantation with the Medtronic Core Valve System, at baseline and discharge. PPM was defined as severe (indexed EOA <0.65 cm(2)/m(2)) or moderate (indexed EOA 0.65 to 0.85 cm(2)/m(2)). The indexed EOA increased from 0.35 +/- 0.13 to 0.97 +/- 0.34 cm(2)/m(2) after transcatheter aortic valve implantation (p <0.001) and was accompanied by significant clinical improvement. Severe and moderate PPMs were found in 16% and 23% of patients, respectively. Patients with severe PPM were more symptomatic and had a smaller indexed EOA at baseline than those with moderate or no PPM (0.28 +/- 0.09 vs 0.36 +/- 0.12 cm(2)/m(2), p <0.05). Functional status and mortality at 30 days and 6 months was not significantly different between the patients with severe PPM and those with moderate or no PPM. In conclusion, the indexed EOA increased significantly after transcatheter aortic valve implantation. Severe PPM was observed in 16% of the patients and was not associated with the clinical outcome. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:255-260)
AB - A prosthesis patient mismatch (PPM) is present when the prosthetic valve is too small in relation to the patient's body size. The purpose of the present study was to investigate the frequency of PPM after the implantation of the Medtronic Core Valve System, and its relation to the clinical outcome. The indexed effective orifice area (EOA) was measured in 74 patients with symptomatic severe aortic stenosis, who had undergone successful transcatheter aortic valve implantation with the Medtronic Core Valve System, at baseline and discharge. PPM was defined as severe (indexed EOA <0.65 cm(2)/m(2)) or moderate (indexed EOA 0.65 to 0.85 cm(2)/m(2)). The indexed EOA increased from 0.35 +/- 0.13 to 0.97 +/- 0.34 cm(2)/m(2) after transcatheter aortic valve implantation (p <0.001) and was accompanied by significant clinical improvement. Severe and moderate PPMs were found in 16% and 23% of patients, respectively. Patients with severe PPM were more symptomatic and had a smaller indexed EOA at baseline than those with moderate or no PPM (0.28 +/- 0.09 vs 0.36 +/- 0.12 cm(2)/m(2), p <0.05). Functional status and mortality at 30 days and 6 months was not significantly different between the patients with severe PPM and those with moderate or no PPM. In conclusion, the indexed EOA increased significantly after transcatheter aortic valve implantation. Severe PPM was observed in 16% of the patients and was not associated with the clinical outcome. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:255-260)
U2 - 10.1016/j.amjcard.2010.02.036
DO - 10.1016/j.amjcard.2010.02.036
M3 - Article
VL - 106
SP - 255
EP - 260
JO - American Journal of Cardiology
JF - American Journal of Cardiology
SN - 0002-9149
IS - 2
ER -