Reduction of Anastomotic Time Through the Use of Cyanoacrylate in Microvascular Procedures

Translated title of the contribution: La réduction du temps d’anastomose grâce au cyanoacrylate pour les interventions microvasculaires

Alex V. Orădan, George C. Dindelegan*, Ramona C. Vinaşi, Maximilian V. Muntean, Maximilian G. Dindelegan, Liviu Chiriac, Victor Volovici

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

4 Citations (Scopus)

Abstract

Background: Ever since the description of the first microvascular anastomosis, numerous alternative methods have been described to the classical approach. Tissue adhesive has shown promising result in previous studies and can be a fast and efficient alternative which still requires more studies to allow its clinical implementation. Methods: A randomized comparative experimental study was conducted on rats’ femoral arteries and an end-to-end anastomosis was performed in order to compare 2 anastomosis techniques. In one group, a simple interrupted suture was utilized, whereas in the second group a combination between fewer sutures and tissue adhesive was used. The anastomotic time, total operative time, blood flow velocity before, immediately after and 48 hours after the procedure, as well as an independent grading of the anastomosis immediately after the procedure were performed. Magnetic resonance imaging (MRI) was performed in order to assess the degree of stenosis. After euthanasia, histology and scanning electron microscopy (SEM) were performed on the vessels in order to assess possible complications. Results: A total of 24 anastomoses were performed, of which 12 with a classic technique and 12 with an adhesive technique. All the anastomoses were patent with a significant reduction of anastomotic and total operative time. The grading of the anastomoses showed better results in the classic suture group. The blood flow velocities were not statistically significant between the 2 groups. On MRI there was one stenotic anastomosis, whereas histology and SEM showed more complications on the adhesive group. Conclusion: Anastomotic times were significantly lower with a non-significant trend toward more thrombotic complications in the adhesive group. Further improvement of the glue properties and refinement of the technique will likely make it a viable alternative to interrupted suturing in the future.

Translated title of the contributionLa réduction du temps d’anastomose grâce au cyanoacrylate pour les interventions microvasculaires
Original languageFrench
Pages (from-to)335-342
Number of pages8
JournalPlastic Surgery
Volume30
Issue number4
Early online date28 May 2021
DOIs
Publication statusPublished - Nov 2022

Bibliographical note

Funding Information:
The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This study was supported by a Doctoral Research Project from “Iuliu Haţieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania [Contract no. 1529/53/January 2018].

Funding Information:
The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This study was supported by a Doctoral Research Project from “Iuliu Haţieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania [Contract no. 1529/53/January 2018].

Publisher Copyright:
© 2021 The Author(s).

Fingerprint

Dive into the research topics of 'La réduction du temps d’anastomose grâce au cyanoacrylate pour les interventions microvasculaires'. Together they form a unique fingerprint.

Cite this