Skip to main navigation Skip to search Skip to main content

Resultados de los stents Resolute Integrity y Promus Element en el infarto de miocardio: análisis del ensayo aleatorizado DUTCH PEERS (TWENTE II)

Translated title of the contribution: Outcome After Myocardial Infarction Treated With Resolute Integrity and Promus Element Stents: Insights From the DUTCH PEERS (TWENTE II) Randomized Trial
  • K. Gert van Houwelingen
  • , Ming Kai Lam
  • , Marije M. Löwik
  • , Peter W. Danse
  • , R. Melvyn Tjon Joe Gin
  • , Gillian A. Jessurun
  • , Rutger L. Anthonio
  • , Hanim Sen
  • , Gerard C.M. Linssen
  • , Maarten J. IJzerman
  • , Carine J.M. Doggen
  • , Clemens von Birgelen*
  • *Corresponding author for this work
  • Medisch Spectrum Twente
  • Rijnstate Hospital
  • Treant Zorggroep, location Scheper
  • University of Twente
  • Ziekenhuisgroep Twente (Almelo)

Research output: Contribution to journalArticleAcademicpeer-review

6 Citations (Scopus)
32 Downloads (Pure)

Abstract

Introduction and objectives In acute myocardial infarction (MI), novel highly deliverable drug-eluting stents (DES) may be particularly valuable as their flexible stent designs might reduce device-induced traumas to culprit lesions. The aim of the study was to assess the safety and efficacy of percutaneous coronary interventions with 2 novel durable polymer-coated DES in patients with acute MI. Methods The prospective, randomized DUTCH PEERS (TWENTE II) multicenter trial compares Resolute Integrity and Promus Element stents in 1811 all-comer patients, of whom 817 (45.1%) were treated for ST-segment elevation MI or non—ST-segment elevation MI and the 2-year outcome is available in 99.9%. The primary clinical endpoint is target vessel failure (TVF), a composite of cardiac death, target vessel related MI, or target vessel revascularization. Results Of all 817 patients treated for acute MI, 421 (51.5%) were treated with Resolute Integrity and 396 (48.5%) with Promus Element stents. At the 2-year follow-up, the rates of TVF (7.4% vs 6.1%; P =.45), target lesion revascularization (3.1% vs 2.8%; P =.79), and definite stent thrombosis (1.0% vs 0.5%; P =.69) were low for both stent groups. Consistent with these findings in all patients with acute MI, outcomes for the 2 DES were favorable and similar in both, with 370 patients with ST-segment elevation MI (TVF: 5.1% vs 4.9%; P =.81) and 447 patients with non—ST-segment elevation MI (TVF: 9.0% vs 7.5%; P =.56). Conclusions Resolute Integrity and Promus Element stents were both safe and efficacious in treating patients with acute MI. The present 2-year follow-up data underline the safety of using these devices in this particular clinical setting. Full English text available from: www.revespcardiol.org/en

Translated title of the contributionOutcome After Myocardial Infarction Treated With Resolute Integrity and Promus Element Stents: Insights From the DUTCH PEERS (TWENTE II) Randomized Trial
Original languageSpanish
Pages (from-to)1152-1159
Number of pages8
JournalRevista Espanola de Cardiologia
Volume69
Issue number12
DOIs
Publication statusPublished - 1 Dec 2016

Bibliographical note

FUNDING:
The investigator-initiated, randomized DUTCH PEERS trial was
funded by equal research grants from Boston Scientific and
Medtronic.

Publisher Copyright:
© 2016 Sociedad Española de Cardiología

Fingerprint

Dive into the research topics of 'Outcome After Myocardial Infarction Treated With Resolute Integrity and Promus Element Stents: Insights From the DUTCH PEERS (TWENTE II) Randomized Trial'. Together they form a unique fingerprint.

Cite this