TY - JOUR
T1 - Scaffold and Edge Vascular Response Following Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffold A 3-Year Serial Optical Coherence Tomography Study
AU - Zhang, Y
AU - Iqbal, Iqbal
AU - Nakatani, S
AU - Bektas, Fatma
AU - Campos, CA
AU - Ishibashi, Y
AU - Cho, YK
AU - Veldhof, S
AU - Wang, Johnny
AU - Onuma, Yoshinobu
AU - Garcia Garcia, Hector
AU - Dudek, D
AU - van Geuns, Robert Jan
AU - Serruys, PWJC (Patrick)
PY - 2014
Y1 - 2014
N2 - OBJECTIVES This study sought to investigate the in-scaffold vascular response (SVR) and edge vascular response (EVR) after implantation of an everolimus-eluting bioresorbable scaffold (BRS) using serial optical coherence tomography (OCT) imaging. BACKGROUND Although studies using intravascular ultrasound have evaluated the EVR in metal stents and BRSs, there is a lack of OCT-based SVR and EVR assessment after BRS implantation. METHODS In the ABSORB Cohort B (ABSORB Clinical Investigation, Cohort B) study, 23 patients (23 lesions) in Cohort B1 and 17 patients (18 lesions) in Cohort B2 underwent truly serial OCT examinations at 3 different time points (Cohort B1: post-procedure, 6 months, and 2 years; B2: post-procedure, 1 year, and 3 years) after implantation of an 18-mm scaffold. A frame-by-frame OCT analysis was performed at the 5-mm proximal, 5-mm distal edge, and 2-mm in-scaffold margins, whereas the middle 14-mm in-scaffold segment was analyzed at 1-mm intervals. RESULTS The in-scaffold mean luminal area significantly decreased from baseline to 6 months or 1 year (7.22 +/- 1.24 mm(2) vs. 6.05 +/- 1.38 mm(2) and 7.64 +/- 1.19 mm(2) vs. 5.72 +/- 0.89 mm(2), respectively; both p < 0.01), but remained unchanged from then onward. In Cohort B1, a significant increase in mean luminal area of the distal edge was observed (5.42 +/- 1.81 mm(2) vs. 5.58 +/- 1.53 mm(2); p < 0.01), whereas the mean luminal area of the proximal edge remained unchanged at 6 months. In Cohort B2, the mean luminal areas of the proximal and distal edges were significantly smaller than post-procedure measurements at 3 years. The mean luminal area loss at both edges was significantly less than the mean luminal area loss of the in-scaffold segment at both 6-month and 2-year follow-up in Cohort B1 or at 1 year and 3 years in Cohort B2. CONCLUSIONS This OCT-based serial EVR and SVR evaluation of the Absorb Bioresorbable Vascular Scaffold (Abbott Vascular, Santa Clara, California) showed less luminal loss at the edges than luminal loss within the scaffold. The luminal reduction of both edges is not a nosologic entity, but an EVR in continuity with the SVR, extending from the in-scaffold margin to both edges. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856) (C) 2014 by the American College of Cardiology Foundation.
AB - OBJECTIVES This study sought to investigate the in-scaffold vascular response (SVR) and edge vascular response (EVR) after implantation of an everolimus-eluting bioresorbable scaffold (BRS) using serial optical coherence tomography (OCT) imaging. BACKGROUND Although studies using intravascular ultrasound have evaluated the EVR in metal stents and BRSs, there is a lack of OCT-based SVR and EVR assessment after BRS implantation. METHODS In the ABSORB Cohort B (ABSORB Clinical Investigation, Cohort B) study, 23 patients (23 lesions) in Cohort B1 and 17 patients (18 lesions) in Cohort B2 underwent truly serial OCT examinations at 3 different time points (Cohort B1: post-procedure, 6 months, and 2 years; B2: post-procedure, 1 year, and 3 years) after implantation of an 18-mm scaffold. A frame-by-frame OCT analysis was performed at the 5-mm proximal, 5-mm distal edge, and 2-mm in-scaffold margins, whereas the middle 14-mm in-scaffold segment was analyzed at 1-mm intervals. RESULTS The in-scaffold mean luminal area significantly decreased from baseline to 6 months or 1 year (7.22 +/- 1.24 mm(2) vs. 6.05 +/- 1.38 mm(2) and 7.64 +/- 1.19 mm(2) vs. 5.72 +/- 0.89 mm(2), respectively; both p < 0.01), but remained unchanged from then onward. In Cohort B1, a significant increase in mean luminal area of the distal edge was observed (5.42 +/- 1.81 mm(2) vs. 5.58 +/- 1.53 mm(2); p < 0.01), whereas the mean luminal area of the proximal edge remained unchanged at 6 months. In Cohort B2, the mean luminal areas of the proximal and distal edges were significantly smaller than post-procedure measurements at 3 years. The mean luminal area loss at both edges was significantly less than the mean luminal area loss of the in-scaffold segment at both 6-month and 2-year follow-up in Cohort B1 or at 1 year and 3 years in Cohort B2. CONCLUSIONS This OCT-based serial EVR and SVR evaluation of the Absorb Bioresorbable Vascular Scaffold (Abbott Vascular, Santa Clara, California) showed less luminal loss at the edges than luminal loss within the scaffold. The luminal reduction of both edges is not a nosologic entity, but an EVR in continuity with the SVR, extending from the in-scaffold margin to both edges. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856) (C) 2014 by the American College of Cardiology Foundation.
U2 - 10.1016/j.jcin.2014.06.025
DO - 10.1016/j.jcin.2014.06.025
M3 - Article
C2 - 25457053
SN - 1936-8798
VL - 7
SP - 1361
EP - 1369
JO - JACC-Cardiovascular interventions
JF - JACC-Cardiovascular interventions
IS - 12