99mTc-MAG3 diuretic renography in diagnosis of obstructive nephropathy in adults: A comparison between F-15 and a new procedure F+10(sp) in seated position

  • Girolamo Tartaglione
  • , Alessandro D'Addessi
  • , Chiara De Waure
  • , Marco Pagan
  • , Marco Raccioppi
  • , Emilio Sacco
  • , Chiara Cadeddu
  • , Matteo Vittori
  • , Pier Francesco Bassi
  • , Alice Ferretti
  • , Adil Al-Nahhas
  • , Domenico Rubello*
  • *Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

17 Citations (Scopus)

Abstract

OBJECTIVE: 

The objective of this study was to compare 2 diuretic renography procedures: F-15 versus F+10(sp) for diagnosis of obstructive uropathy in adults. 

METHODS: 

Thirty-six patients with unilateral or bilateral hydronephrosis had 2 consecutive Tc-MAG3 diuretic renograms within 7 days, using the widely used procedure F-15 in supine position, and a new seated-position procedure whereby the patient drinks 400 to 500 mL of water at 5 minutes and receives an injection of 20 mg of furosemide at 10 minutes [F+10 (sp)]. 

RESULTS: 

F-15 showed nonobstructive results in 63.9% of kidneys, obstruction in 26.4%, and equivocal findings in 6.9% and was not applicable in 2.8%. F+10(sp) showed nonobstructive results in 70.9%, obstruction in 27.8%, and equivocal result in 1.4% of kidneys. Nephroptosis was observed by F+10(sp) in 22.2% of kidneys. Adverse effects reported for the F-15 were hypotension in 2 patients, renal colic in 3 patients, and interruption due to voiding in 5 patients. No adverse effects were reported for F+10(sp). 

CONCLUSIONS: 

This study shows that the F+10(sp) procedure reduces the equivocal findings of F-15 procedure in 36 patients. It can improve the accuracy and compliance, avoiding adverse effects and reducing bladder filling-related problems.

Original languageEnglish
Pages (from-to)432-436
Number of pages5
JournalClinical Nuclear Medicine
Volume38
Issue number6
DOIs
Publication statusPublished - Jun 2013
Externally publishedYes

Fingerprint

Dive into the research topics of '99mTc-MAG3 diuretic renography in diagnosis of obstructive nephropathy in adults: A comparison between F-15 and a new procedure F+10(sp) in seated position'. Together they form a unique fingerprint.

Cite this