N2 - Introduction: Conventional implantable cardioverter-defibrillators (ICDs) and pacemakers carry a risk of pocket- and lead-related complications in particular. To avoid these complications, extravascular devices (EVDs) have been developed, such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP). However, data on patient or centre characteristics related to the actual adoption of EVDs are lacking. Objective: To assess real-world nationwide trends in EVD adoption in the Netherlands. Methods: Using the Netherlands Heart Registration, all consecutive patients with a de novo S‑ICD or conventional single-chamber ICD implantation between 2012–2020, or de novo LP or conventional single-chamber pacemaker implantation between 2014–2020 were included. Trends in adoption are described for various patient and centre characteristics. Result: From 2012–2020, 2190 S‑ICDs and 10,683 conventional ICDs were implanted; from 2014–2020, 712 LPs and 11,103 conventional pacemakers were implanted. The general use has increased (S-ICDs 8 to 21%; LPs 1 to 8%), but this increase seems to have reached a plateau. S‑ICD recipients were younger than conventional ICD recipients (p < 0.001) and more often female (p < 0.001); LP recipients were younger than conventional pacemaker recipients (p < 0.001) and more often male (p = 0.03). Both S‑ICDs and LPs were mainly implanted in high-volume centres with cardiothoracic surgery on-site, although over time S‑ICDs were increasingly implanted in centres without cardiothoracic surgery (p < 0.001). Conclusion: This nationwide study demonstrated a relatively quick adoption of innovative EVDs with a plateau after approximately 4 years. S‑ICD use is especially high in younger patients. EVDs are mainly implanted in high-volume centres with cardiothoracic surgery back-up, but S‑ICD use is expanding beyond those centres.
AB - Introduction: Conventional implantable cardioverter-defibrillators (ICDs) and pacemakers carry a risk of pocket- and lead-related complications in particular. To avoid these complications, extravascular devices (EVDs) have been developed, such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP). However, data on patient or centre characteristics related to the actual adoption of EVDs are lacking. Objective: To assess real-world nationwide trends in EVD adoption in the Netherlands. Methods: Using the Netherlands Heart Registration, all consecutive patients with a de novo S‑ICD or conventional single-chamber ICD implantation between 2012–2020, or de novo LP or conventional single-chamber pacemaker implantation between 2014–2020 were included. Trends in adoption are described for various patient and centre characteristics. Result: From 2012–2020, 2190 S‑ICDs and 10,683 conventional ICDs were implanted; from 2014–2020, 712 LPs and 11,103 conventional pacemakers were implanted. The general use has increased (S-ICDs 8 to 21%; LPs 1 to 8%), but this increase seems to have reached a plateau. S‑ICD recipients were younger than conventional ICD recipients (p < 0.001) and more often female (p < 0.001); LP recipients were younger than conventional pacemaker recipients (p < 0.001) and more often male (p = 0.03). Both S‑ICDs and LPs were mainly implanted in high-volume centres with cardiothoracic surgery on-site, although over time S‑ICDs were increasingly implanted in centres without cardiothoracic surgery (p < 0.001). Conclusion: This nationwide study demonstrated a relatively quick adoption of innovative EVDs with a plateau after approximately 4 years. S‑ICD use is especially high in younger patients. EVDs are mainly implanted in high-volume centres with cardiothoracic surgery back-up, but S‑ICD use is expanding beyond those centres.
UR - https://www.scopus.com/pages/publications/85201552876
U2 - 10.1007/s12471-024-01892-6
DO - 10.1007/s12471-024-01892-6
M3 - Article
C2 - 39158682
SN - 1568-5888
VL - 32
SP - 356
EP - 362
JO - Netherlands Heart Journal
JF - Netherlands Heart Journal
IS - 10
ER -