TY - JOUR
T1 - Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure
AU - Maissan, Iscander
AU - Dirven, PJA
AU - Haitsma, Iain
AU - Hoeks, Sanne
AU - Gommers, Diederik
AU - Stolker, Robert jan
PY - 2015
Y1 - 2015
N2 - OBJECT Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) is known to be an accurate monitor of elevated intracranial pressure (ICP). However, it is yet unknown whether fluctuations in ICP result in direct changes in ONSD. Therefore, the authors researched whether ONSD and ICP simultaneously change during tracheal manipulation in patients in the intensive care unit (ICU) who have suffered a traumatic brain injury (TBI). MATERIALS The authors included 18 ICP-monitored patients who had sustained TBI and were admitted to the ICU. They examined the optic nerve sheath by performing ultrasound before, during, and after tracheal manipulation, which is known to increase ICP. The correlation between ONSD and ICP measurements was determined, and the diagnostic performance of ONSD measurement was tested using receiver operating characteristic curve analysis. RESULTS In all patients ICP increased above 20 mm Hg during manipulation of the trachea, and this increase was directly associated with a dilation of the ONSD of > 5.0 mm. After tracheal manipulation stopped, ICP as well as ONSD decreased immediately to baseline levels. The correlation between ICP and ONSD was high (R-2 = 0.80); at a cutoff of >= 5.0 mm ONSD, a sensitivity of 94%, a specificity of 98%, and an area under the curve of 0.99 (95% CI 0.97-1.00) for detecting elevated ICP were determined. CONCLUSIONS In patients who have sustained a TBI, ultrasonography of the ONSD is an accurate, simple, and rapid measurement for detecting elevated ICP as well as immediate changes in ICP. Therefore, it might be a useful tool to monitor ICP, especially in conditions in which invasive ICP monitoring is not available, such as at trauma scenes.
AB - OBJECT Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) is known to be an accurate monitor of elevated intracranial pressure (ICP). However, it is yet unknown whether fluctuations in ICP result in direct changes in ONSD. Therefore, the authors researched whether ONSD and ICP simultaneously change during tracheal manipulation in patients in the intensive care unit (ICU) who have suffered a traumatic brain injury (TBI). MATERIALS The authors included 18 ICP-monitored patients who had sustained TBI and were admitted to the ICU. They examined the optic nerve sheath by performing ultrasound before, during, and after tracheal manipulation, which is known to increase ICP. The correlation between ONSD and ICP measurements was determined, and the diagnostic performance of ONSD measurement was tested using receiver operating characteristic curve analysis. RESULTS In all patients ICP increased above 20 mm Hg during manipulation of the trachea, and this increase was directly associated with a dilation of the ONSD of > 5.0 mm. After tracheal manipulation stopped, ICP as well as ONSD decreased immediately to baseline levels. The correlation between ICP and ONSD was high (R-2 = 0.80); at a cutoff of >= 5.0 mm ONSD, a sensitivity of 94%, a specificity of 98%, and an area under the curve of 0.99 (95% CI 0.97-1.00) for detecting elevated ICP were determined. CONCLUSIONS In patients who have sustained a TBI, ultrasonography of the ONSD is an accurate, simple, and rapid measurement for detecting elevated ICP as well as immediate changes in ICP. Therefore, it might be a useful tool to monitor ICP, especially in conditions in which invasive ICP monitoring is not available, such as at trauma scenes.
U2 - 10.3171/2014.10.JNS141197
DO - 10.3171/2014.10.JNS141197
M3 - Article
C2 - 25955869
SN - 0022-3085
VL - 123
SP - 743
EP - 747
JO - Journal of Neurosurgery
JF - Journal of Neurosurgery
IS - 3
ER -