Value of Computed Tomographic Perfusion-Based Patient Selection for Intra-Arterial Acute Ischemic Stroke Treatment

J Borst, Olvert Berkhemer, YBWEM (Yvo) Roos, E van Bavel, WH Zwam, RJ van Oostenbrugge, Marianne Walderveen, Hester Lingsma, Aad van der Lugt, Diederik Dippel, AJ Yoo, HA Marquering, CBLM Majoie

Research output: Contribution to journalArticleAcademicpeer-review

97 Citations (Scopus)

Abstract

Background and Purpose-The utility of computed tomographic perfusion (CTP)-based patient selection for intra-arterial treatment of acute ischemic stroke has not been proven in randomized trials and requires further study in a cohort that was not selected based on CTP. Our objective was to study the relationship between CTP-derived parameters and outcome and treatment effect in patients with acute ischemic stroke because of a proximal intracranial arterial occlusion. Methods-We included 175 patients who underwent CTP in the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in The Netherlands (MR CLEAN). Association of CTP-derived parameters (ischemic-core volume, penumbra volume, and percentage ischemic core) with outcome was estimated with multivariable ordinal logistic regression as an adjusted odds ratio for a shift in the direction of a better outcome on the modified Rankin Scale. Interaction between CTP-derived parameters and treatment effect was determined using multivariable ordinal logistic regression. Interaction with treatment effect was also tested for mismatch (core <70 mL; penumbra core >1.2; penumbra core >10 mL). Results-The adjusted odds ratio for improved functional outcome for ischemic core, percentage ischemic core, and penumbra were 0.79 per 10 mL (95% confidence interval: 0.71-0.89; P<0.001), 0.82 per 10% (95% confidence interval: 0.66-0.90; P=0.002), and 0.97 per 10 mL (96% confidence interval: 0.92-1.01; P=0.15), respectively. No significant interaction between any of the CTP-derived parameters and treatment effect was observed. We observed no significant interaction between mismatch and treatment effect. Conclusions-CTP seems useful for predicting functional outcome, but cannot reliably identify patients who will not benefit from intra-arterial therapy.
Original languageUndefined/Unknown
Pages (from-to)3375-3382
Number of pages8
JournalStroke
Volume46
Issue number12
DOIs
Publication statusPublished - 2015

Research programs

  • EMC COEUR-09
  • EMC NIHES-02-65-01
  • EMC NIHES-03-30-01

Cite this