Purpose: Evaluation of high-resolution 2D-RARE MRCP in the diagnosis of pancreaticobiliary diseases.

Materials and Methods: 23 patients with various pancreaticobiliary diseases were evaluated using conventional and high- resolution 2D-RARE sequences.

Results: High-resolution RARE MRCP allowed for improved delineation of biliary and pancreatic ducts at the expense of reduced signal-to-noise ratio. Pathological findings were significantly (p<0.001) better demonstrated with high resolution RARE MRCP (score 1.65 ± 0.54) as compared to the conventional RARE sequence (score 2.58±0.62).

Conclusions: High-resolution 2D-RARE-MRCP improves the delineation of biliary and pancreatic ducts. This sequence should replace the conventional 2D-RARE sequence.

Translated title of the contributionComparison of conventional and high-resolution 2D-RARE-MRCP in the evaluation of pancreaticobiliary diseases
Original languageGerman
Pages (from-to)254-257
Number of pages4
JournalRoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren
Volume171
Issue number3
Publication statusPublished - Sept 1999

Bibliographical note

Cop. Georg Thieme Verlag Stuttgart-New York

Fingerprint

Dive into the research topics of 'Comparison of conventional and high-resolution 2D-RARE-MRCP in the evaluation of pancreaticobiliary diseases'. Together they form a unique fingerprint.

Cite this